The tensile strength of human tendons

TENSILE STRENGTH OF HUMAN TENDONS. 175. Pioe plantaris ten- dons from 21 to. 74 years old, and onc flexor hallu- cis longus, age not given, 3 to. 4 days post mor tem rwo 'tibialis ex- terniis ' tendons of a dog im- mediately after death. h e plantaris ten- don of woman 30 years old, ob taiticd at opera- tion. h e palninris ...

pdf

stress-strain characteristics and tensile strength of unembalmed

Abstract-ln an effort to determine more accurately the physical characteristics of human tendon, stress-strain and tensile strength studies were performed on tendons removed from amputated lower limbs. The tendons of M. extensor digitontm longus, M. extensor digitonun brevis, M. extensor hallucis longus, M. flexor ...

pdf?md5=73ec64c2ebc1dc6a9977de28f2941c2b&pid=1-s2.0-0021929068900389-main.pdf

Tensile properties of fresh human calcaneal (achilles) tendons

The purpose of this study was to measure the tensile properties of fresh human calcaneal. (Achilles) tendons. Twenty fresh cadaveric (age range. 57–93 years) bone-Achilles tendon complexes were harvested within 24 hr postmortem. The calcaneus together with 15 cm of the Achilles tendon extending proximally from the ...

pdf

Time-Dependent Alterations of MMPs, TIMPs and Tendon Structure

Oct 20, 2017 ... Variation in this balance over time might impact on the success of tendon healing . This study aimed to analyze structural changes and the expression profile of MMPs and TIMPs in human Achilles tendons at different time-points after rupture. Biopsies from. 37 patients with acute Achilles tendon rupture were ...

pdf

Biomechanical Behavior of Muscle-Tendon Complex During

2006 Human Kinetics, Inc. Biomechanical Behavior of Muscle-Tendon Complex. During Dynamic Human Movements. Senshi Fukashiro1, Dean C. Hay2 and Akinori Nagano3. 1,2University of Tokyo; 3RIKEN, Japan. This paper reviews the research findings regarding the force and length changes of the muscle-tendon ...

5722.pdf

Mechanical stimulation of human tendon stem/progenitor cells

Background. Tendons are dense connective tissues subjected periodically to mechanical stress upon which complex responsive mechanisms are activated. These mechanisms affect not only the development of these tissues but also their healing. Despite of the acknowledged importance of the mechanical stress for tendon ...

Mechanical-stimulation-of-human-tendon-stem-progenitor-cells-results-in-upregulation-of-matrix-proteins-integrins-and-MMPs-and-activation-of-p38-and-ERK1-2-kinases.pdf

Effects of Creep and Cyclic Loading on the Mechanical Properties

The Achilles tendon is one of the most frequently injured tendons in humans, and yet the mechanisms underlying its injury are not well understood. This study examines the ex vivo mechanical behavior of excised human Achilles tendons to elucidate the relationships between mechanical loading and Achilles tendon injury.

q6n46r6700841862.pdf

changes in the collagen composition of the human rotator cuff

Annals ofthe Rheumatic Diseases 1994; 53: 359-366. EXTENDED REPORTS. Tendon degeneration and chronic shoulder pain: changes in the collagen composition of the human rotator cuff tendons in rotator cuff tendinitis. G P Riley, R L Harrall, C R Constant, M D Chard, T E Cawston, B L Hazleman. Addenbrooke's.

359.full.pdf

Effects of Creep and Cyclic Loading on the Mechanical Properties

Abstract—The Achilles tendon is one of the most frequently injured tendons in humans, and yet the mechanisms underlying its injury are not well understood. This study examines the ex vivo mechanical behavior of excised human Achilles tendons to elucidate the relationships between mechanical loading and. Achilles  ...

1.1569267.pdf

age related changes to mechanical and matrix properties in human

Poster Session - Ligament and Tendon Biology - Hall E. 47th Annual Meeting, Orthopaedic Research Society, February 25 - 28, 2001, San Francisco, California . 0713. AGE RELATED CHANGES TO MECHANICAL AND MATRIX PROPERTIES IN HUMAN ACHILLES TENDON. +*Birch, H (A-Arthritis Research Campaign); ...

0713.pdf

Three-Dimensional infrastructure of Human Tendons

Apr 25, 1991 ... Abstract. The three-dimensional ultrastructure of human tendons has been studied. Epitenon and peritenon consis of a dense network of longitudinal, oblique and transversal collagen fibrils crossing the tendon fibres. The interna structure of tendon fibres is also complex. The collagen fibrils are oriented not ...

147207

1085 - fibrocartilage in the extensor tendons of the human

Glycosaminoglycan Fibrocartilage Human. FIBROCARTILAGE IN THE EXTENSOR TENDONS OF THE HUMAN METACARPOPHALANGEAL JOINTS. *+Milz S., *+Putz R., **Ralphs J.R. and **Benjamin M.,. + Dept. of Anatomy, Pettenkoferstr.11, D-80336 Muenchen, Phone: +498951604844, Fax.: + 498951604802,.

1085.PDF

characterization of tendon cell cultures of the human rotator cuff

human rotator cuff tendon cell culture. Long head biceps (LHB)- and supraspinatus muscle. (SSP)- tendon samples from donor patients undergoing shoulder surgery were cultivated and examined at the RNA level for expression of collagen type-I, -II and -III, biglycan, decorin, tenascin-C, aggrecan, osteocalcin , tenomodulin.

v020a08.pdf

Hysteresis measurements in intact human tendon

Technical note. Hysteresis measurements in intact human tendon. Constantinos N. Maganaris* , John P. Paul. University of Strathclyde, Glasgow UK. Accepted 26 May 2000. Abstract. Mechanical hysteresis in tendons has traditionally been quanti"ed from tensile testing of isolated specimens. Limitations associated.

pdf

In vivo mechanical response of human Achilles tendon to a single

Both animal and human tendons have been shown to fatigue in vitro under continuous static or cyclic loading. In vitro, fatigue is often expressed as a decrease in the ultimate stress of a tendon; the stress that the tendon can bear without rupture. When rupture occurs after static loading, it is referred to as a creep rupture, and ...

1259.full.pdf

In vivo human tendon mechanical properties: Effect of resistance

Although the primary role of tendons is to transmit con- tractile forces to the skeleton to generate joint movement, tendons do not behave as rigid bodies. Instead, they exhibit a viscoelastic behaviour on tension, which has important implications for whole-body function for reasons that include: a) modulation of the length and ...

3e1348c19e30c262402a696a80b6bb5556c8.pdf

Ligaments and Tendons of the Human Body.pdf

LIGAMENTS AND TENDONS OF THE HUMAN BODY. Lm. acromioclaviculare acromioclavicular l. Connects acromion to clavicle; strengthens articular capsule. Lm. anulare radii anular l. of radius. Connects head of radius in radial notch. Lm. collaterale ulnare collateral ulnar l. Connects medial epicondyle to humerus and  ...

APP14.pdf

Metabolic activity and collagen turnover in human tendon in

Dec 8, 2004 ... I and III collagens are the most abundant tendon collagens and are produced principally by fibroblasts on the mem-. J Musculoskelet Neuronal Interact 2005; 5( 1):41-52. Metabolic activity and collagen turnover in human tendon in response to physical activity. M. Kjaer, H. Langberg, B.F. Miller, R. Boushel, ...

07KJAER.pdf

Mechanical properties of the human achilles tendon

Abstract. Objective. To determine whether the human Achilles tendon has higher material properties than other tendons and to test for strain rate sensitivity of the tendon. Design. Mechanical testing of excised tendons. Background. While the human Achilles tendon appears to experience higher in vivo stresses than other  ...

Wren 2001 ClinBM - Achilles_failure.pdf

Dynamic Characterization of Human Tendons

Apr 20, 1994 ... Dynamic characterization of human tendons. H Schechtman, BSc, MSc and D L Bader, BSc, MSc, PhD. Interdisciplinary Research Centre in Biomedical Materials , Queen Mary and Westfield College, University of London. Human tendons were tested in uniaxial tension with the use of specially designed ...

PIME_PROC_1994_208_294_02